Create the workspace
- On conductcommons.com, choose Start free and create your ConductScience account. If you already have one, choose Sign in instead.
- On the Create a workspace page, answer What are you setting up? with Core facility or Research lab.
- Type the name under Core facility name or Lab name. The address of the workspace appears under the name. Institution is optional.
- Choose Create core facility or Create lab.
| Type | What it is for | Opens on |
|---|---|---|
| Core facility | Shared instruments that researchers from other labs book: scheduling, training, approvals, and billing. | Schedule |
| Research lab | Your own lab: inventory, equipment, locations, and budgets. | Dashboard |
The address is https://app.conductcommons.com/ followed by the name in lowercase, with hyphens between the words. If a ConductCommons page or another workspace already uses that address, the app asks you to change the name.
You are the owner of the workspace you create. Every new workspace includes the Core plan for 30 days.
To change the type later, a manager opens Settings and, under Workspace type, chooses Switch to research lab or Switch to core facility. Switching changes the menu and home page for everyone in the workspace. Nothing is deleted.
Add instruments
An instrument is anything people book: a microscope, a testing room, a maze, a workstation. Only managers can add, edit, or retire instruments. There are three ways to add them.
Pick from the starter list
A workspace with no instruments shows the starter list on Schedule. Later, open it from Schedule, then Equipment & access, then + Add instruments. The list has more than 100 instruments, rooms, and apparatus in six groups.
- Tick each instrument your core has. Open a group to see its instruments, or type in Find an instrument. Under each name you see the rules it starts with, such as Training or Protocol number.
- If you have more than one of an instrument, set How many, up to 20. Three operant chambers are added as Operant chamber 1, Operant chamber 2, and Operant chamber 3.
- Type anything that is not on the list under Anything else? One per line.
- Choose the button at the bottom. It shows your count, for example Add 3 instruments and open for booking. You can add up to 60 at a time.
Each instrument opens for booking at once, with rates of $0. A name you typed takes the rules of the listed instrument it matches; any other name opens with no extra rules. A name that is already in the workspace is skipped. If an instrument requires training, you are recorded as trained on it, so you can book it yourself.
Start from your kind of core
Above the list, Start from your kind of core sets the core up for one kind of work in one step. Choose a kind and its instruments are ticked for you. Change any of them before you continue.
The button then names the kind, for example Set up as a light microscopy core. Along with the instruments it adds the kind's services, with their request questions, and its maintenance plans on each instrument they apply to.
| Kind | Instruments ticked | Services | Maintenance plans |
|---|---|---|---|
| Flow cytometry | Flow cytometer (2), Spectral flow cytometer, Cell sorter, Biosafety cabinet, Cell counter | Assisted cell sorting, per hour; Panel design consultation, per hour | Daily QC with beads, every day; Weekly fluidics cleaning, every week; Preventive maintenance visit, every 6 months; Biosafety cabinet certification, every year |
| Light microscopy | Confocal microscope (2), Fluorescence microscope, Two-photon microscope, Super-resolution microscope, Light-sheet microscope, Live-cell imaging system, Slide scanner, Image analysis workstation (2) | Assisted imaging, per hour; Slide scanning, per sample; Image analysis consultation, per hour | Objective and stage cleaning, every week; Laser power and bead check, every month; Environmental chamber cleaning, every month; Clear old data from the local drive, every month; Preventive maintenance visit, every year |
| NMR | NMR spectrometer (3), Data processing workstation (2), Chemical fume hood | NMR sample run by staff, per sample; Spectrum processing and interpretation help, per hour | Liquid nitrogen fill, every week; Lineshape and sensitivity check, every month; Liquid helium fill, every 3 months; Clear old data from the local drive, every month; Preventive maintenance visit, every year |
| Histology | Tissue processor, Tissue embedding station, Microtome (2), Cryostat, Automated slide stainer, Coverslipper, Automated IHC stainer, Slide scanner, Chemical fume hood | Processing, embedding, and H&E, per sample; Unstained sections, per sample; Frozen sections, per sample; Special stains, per sample; Immunohistochemistry (IHC), per sample; Histology training or assisted sectioning, per hour | Rotate processing reagents, every week; Clean the retort and wax baths, every month; Clean the wax trays and cold plate, every week; Clean and oil the microtome, every week; Defrost and disinfect the cryostat, every month; Change staining reagents, every week; Refill mounting medium and clean the nozzle, every week; Clean the optics and slide trays, every month; Fume hood airflow check, every year; Preventive maintenance visit, every year |
| Genomics | Sequencer (2), Long-read sequencer, Single-cell partitioning system, Fragment analyzer, Fluorometer, Spectrophotometer, qPCR system, Digital PCR system, Thermal cycler (2), Liquid handling robot, Sonicator | Library prep and sequencing, per sample; Sequencing of ready-made libraries, per sample; Single-cell library prep, per sample; Sample QC (DNA or RNA), per sample; Sanger sequencing, per sample; Sequencing data analysis help, per hour | Maintenance wash, every month; Clear old run data, every month; Clean and run a ladder check, every month; Measure the calibration standards, every month; Block temperature check, every year; Clean the deck and check pipetting, every month; Change and degas the water bath, every week; Preventive maintenance visit, every year |
| Sequencing | Sequencer (2), Long-read sequencer, Capillary DNA analyzer, Fragment analyzer, Fluorometer, qPCR system, Thermal cycler (2), Liquid handling robot, Nucleic acid extraction system | Whole sequencing run, per request; Libraries on a shared run, per sample; Sanger sequencing, per sample; Whole-plasmid sequencing, per sample; Amplicon sequencing, per sample; Fragment analysis, per sample; DNA or RNA extraction, per sample; Sequencing data analysis help, per hour | Maintenance wash, every month; Clear old run data, every month; Replace the polymer and buffer, every week; Run the sequencing standard, every month; Clean and run a ladder check, every month; Measure the calibration standards, every month; Block temperature check, every year; Clean the deck and check pipetting, every month; Clean and decontaminate, every week; Preventive maintenance visit, every year |
| Proteomics | Mass spectrometer (2), HPLC system, Vacuum concentrator, Sonicator, Centrifuge, Plate reader, Liquid handling robot, Data processing workstation (2) | Protein identification, per sample; Label-free quantification, per sample; Isobaric labeling (TMT), per sample; Phosphoproteomics, per sample; PTM mapping, per sample; Intact protein mass, per sample; Targeted quantification, per sample; Proteomics data analysis help, per hour | Run the QC standard, every week; Mass calibration, every week; Clean the ion source, every month; Replace the trap and analytical columns, every 3 months; Purge the pumps and check the pressure, every month; Clean the chamber and check the vacuum, every month; Change and degas the water bath, every week; Clean the deck and check pipetting, every month; Archive raw files and clear space, every month; Preventive maintenance visit, every year |
| Mass spectrometry | Triple quadrupole LC-MS/MS (2), Mass spectrometer, GC-MS system, ICP-MS system, MALDI-TOF mass spectrometer, Open-access LC-MS, HPLC system, Nitrogen evaporator, Centrifuge, Data processing workstation (2) | Targeted quantification (LC-MS/MS), per sample; Accurate mass (HRMS), per sample; Compound identification, per sample; GC-MS analysis, per sample; Elemental analysis (ICP-MS), per sample; MALDI-TOF analysis, per sample; Method development, per hour; Mass spectrometry data analysis help, per hour | Run the system suitability standard, every week; Mass calibration, every week; Tune and calibrate, every month; Clean the ion source, every month; Autotune, every week; Change the inlet liner and septum, every month; Run the performance check, every week; Clean the cones, every month; Purge the pumps and check the pressure, every month; Archive raw files and clear space, every month; Preventive maintenance visit, every year |
| Metabolomics | Mass spectrometer (2), Triple quadrupole LC-MS/MS, GC-MS system, Homogenizer, Centrifuge, Vacuum concentrator, Nitrogen evaporator, Freeze dryer, Liquid handling robot, Data processing workstation (2) | Untargeted metabolomics (LC-MS), per sample; Targeted metabolite panel, per sample; Lipidomics, per sample; Stable isotope tracing, per sample; GC-MS metabolite profiling, per sample; Metabolite extraction, per sample; Metabolomics data analysis help, per hour | Run the system suitability standard, every week; Mass calibration, every week; Tune and calibrate, every month; Clean the ion source, every month; Replace the analytical columns, every 3 months; Autotune, every week; Change the inlet liner and septum, every month; Clean the holders and check for wear, every month; Clean the chamber and check the vacuum, every month; Defrost the condenser and check the pump oil, every month; Clean the deck and check pipetting, every month; Archive raw files and clear space, every month; Preventive maintenance visit, every year |
| Electron microscopy | Cryo-electron microscope, Transmission electron microscope (2), Scanning electron microscope, Focused ion beam SEM (FIB-SEM), Ultramicrotome (2), Plunge freezer, High-pressure freezer, Glow discharge system, Sputter coater, Critical point dryer, Data processing workstation (2), Chemical fume hood | Negative stain TEM, per sample; Cryo-EM grid screening, per sample; Cryo-EM data collection, per hour; TEM of cells and tissues, per sample; SEM imaging, per sample; Volume EM (FIB-SEM), per sample; Assisted microscope session, per hour; EM image analysis help, per hour | Check the liquid nitrogen and the autoloader, every day; Cryo-cycle the autoloader and cold trap, every week; Collect a new gain reference, every month; Align the microscope, every week; Check the vacuum and record the gauges, every week; Check the ion beam and record the source hours, every month; Clean and check the knives, every month; Clean the chamber and check the humidity, every month; Clean and check the sample holders, every month; Clean the chamber and check the vacuum, every 3 months; Check the target and clean the chamber, every 3 months; Check the chamber seal and the CO2 supply, every 3 months; Archive raw files and clear space, every month; Fume hood airflow check, every year; Preventive maintenance visit, every year |
| Bioinformatics | GPU compute server, High-memory compute server (2), Data processing workstation (2), Meeting room | RNA-seq analysis, per sample; Variant calling, per sample; Single-cell RNA-seq analysis, per sample; ChIP-seq and ATAC-seq analysis, per sample; Microbiome analysis, per sample; Custom analysis project, per request; Bioinformatics consultation, per hour | Install software and security updates, every month; Check disk health and storage use, every month; Check GPU drivers and temperatures, every month; Archive raw files and clear space, every month; Test restoring files from backup, every 3 months; Review user accounts and access, every 3 months; Hardware check and firmware updates, every year |
| Structural biology | X-ray diffractometer, Crystallization robot, Crystal imaging system (2), Stereo microscope, FPLC system (2), Shaking incubator (2), High-pressure cell disruptor, SEC-MALS system, Dynamic light scattering instrument (DLS), Circular dichroism spectrometer (CD), Differential scanning fluorimeter (nanoDSF), Surface plasmon resonance system (SPR), Bio-layer interferometry system (BLI), Isothermal titration calorimeter (ITC), Cold room, Data processing workstation (2), GPU compute server | Protein expression and purification, per sample; Crystallization screening, per sample; X-ray data collection, per sample; Structure determination project, per request; Biophysical characterization, per sample; Binding analysis, per sample; Assisted instrument session, per hour; Structural biology consultation, per hour | Check the X-ray source and record the beam intensity, every week; Check the cryostream and the chiller water, every month; Test the shutters and safety interlocks, every 3 months; Radiation safety survey, every year; Flush the wash station and check the drops, every week; Calibrate the drop volume, every 3 months; Check the temperature and the image focus, every month; Clean the system and store it in 20% ethanol, every week; Test the column and check the pump seals, every 3 months; Clean the chamber and check the temperature and speed, every month; Check the seals and valves, every 3 months; Run the BSA standard and normalize the detectors, every month; Measure the size standard, every month; Check the nitrogen purge and the lamp hours, every month; Calibrate with camphorsulfonic acid, every 3 months; Clean the cell and run a water titration, every month; Run the calibration titration, every 3 months; Run desorb and sanitize, every month; Run the performance check with a reference sample, every 3 months; Check the temperature log and the door seal, every month; Install software and security updates, every month; Archive raw files and clear space, every month; Check GPU drivers and temperatures, every month; Preventive maintenance visit, every year |
| Viral vector | Tissue culture room, Biosafety cabinet (3), CO2 incubator (3), Shaking incubator, Bioreactor, Centrifuge, Ultracentrifuge (2), FPLC system, Tangential flow filtration system (TFF), Digital PCR system, qPCR system, Flow cytometer, Fluorescence microscope, Cell counter, Plate reader, Spectrophotometer, Gel and blot imager, Autoclave | AAV production, per sample; Lentivirus production, per sample; Adenovirus production, per sample; Plasmid preparation, per sample; Vector titering and QC, per sample; Stock vectors, per request; Custom vector project, per request; Vector consultation, per hour | Test the producer cell lines for mycoplasma, every month; Biosafety inspection of the room, every year; Disinfect the work surface and check the airflow alarm, every week; Biosafety cabinet certification, every year; Clean the chamber and the water pan, every month; Check the CO2 and temperature with a calibrated meter, every 3 months; Clean the chamber and check the temperature and speed, every month; Calibrate the pH and dissolved oxygen sensors, every month; Clean the chamber and inspect the rotors, every month; Clean the system and store it in 20% ethanol, every week; Test the column and check the pump seals, every 3 months; Sanitize the flow path and test the membrane water flux, every month; Run a reference sample of known titer, every month; Block temperature check, every year; Weekly fluidics cleaning, every week; Objective and stage cleaning, every week; Measure the calibration standards, every month; Run a spore test on a waste load, every month; Preventive maintenance visit, every year |
| Biorepository | Ultra-low freezer (4), Liquid nitrogen tank (2), Controlled-rate freezer, Centrifuge (2), Biosafety cabinet (2), CO2 incubator, Cell counter, Nucleic acid extraction system, Spectrophotometer, Fluorometer, Fragment analyzer, Liquid handling robot | Sample banking, per sample; Biospecimen processing, per sample; DNA or RNA extraction, per sample; Cell line cryopreservation, per sample; Specimen release, per sample; Long-term storage, per request; Custom biobanking project, per request; Biorepository consultation, per hour | Check the temperature log and test the alarm, every week; Clean the condenser filter and clear ice from the door seals, every 3 months; Check the nitrogen level and the fill log, every week; Test the low-level and temperature alarms, every month; Run a test program and check the chamber temperature, every 3 months; Clean the chamber and inspect the rotors, every month; Disinfect the work surface and check the airflow alarm, every week; Biosafety cabinet certification, every year; Clean the chamber and the water pan, every month; Clean and decontaminate, every week; Measure the calibration standards, every month; Clean the deck and check pipetting, every month; Preventive maintenance visit, every year |
Services come with the Core plan. On the free plan, choose the same kind of core again after you turn the plan on, and only what is missing is added. A core that does two kinds of work can choose the second kind later from + Add instruments.
Services also come with their stages and usual QC checks where they have them, and with reagents linked to the stock items you already have with the same names, such as Hematoxylin, Eosin, or Microscope slides for histology. Reagents you do not have in stock yet are left out; add them to a service later under Reagents from stock (see Reagents).
Choosing NMR turns on the run queue on each NMR spectrometer, and choosing Mass spectrometry turns it on for the open-access LC-MS. People add their samples, runs go one at a time in order, and runs longer than the day limit wait for the night queue (see Queued runs).
Choosing Biorepository adds services with starter statements to sign: storage terms, samples from people, and use of released samples. Edit them to your core's own terms under Requests, on the Services tab, before researchers send requests (see Statements to sign). Its freezers and liquid nitrogen tanks need a manager's approval to book, so they are there mostly for maintenance plans and problem reports.
Import from a spreadsheet
Use this when you already keep an instrument list in Excel or Google Sheets. Open it with Import your list on the starter list, or from Schedule, then Equipment & access, then Import a list.
- Copy the rows from your sheet, with the header row, and paste them into Paste your list. A pasted table is checked as soon as you paste it. For typed rows, choose Check list.
- Or choose Upload a file for a CSV or Excel (.xlsx) file under 5 MB. Download a sample gives you a file to start from.
- Read the preview. Each row is marked New, Update, or Skipped, with what will happen. You can change a name, a room, or the listed instrument a row takes its rules from, and untick any row you do not want.
- Choose the import button, for example Import 12 instruments.
Columns are matched by their names, so your sheet needs no fixed layout. These columns are read: Name, Room, Type, Internal rate, External rate, Minimum and maximum length, Notice, Days ahead, Training, Approval, Protocol, Charge for, Open for booking, Manufacturer, Model, Serial number, Asset tag, and Notes. Other columns are listed as not imported. A list with no header row is read as instrument names only.
- A new row takes the booking rules of the listed instrument that its name or Type matches. Values in your sheet override those rules.
- A row with the same name as an instrument you already have updates that instrument. Only the values your sheet fills in change.
- Rooms named in the list are created for you.
- One import takes up to 300 rows.
- New instruments open for booking at once, unless the Open for booking column says no. You are recorded as trained on the ones that need training.
- Only hourly rates can be imported, and rates are part of the Core plan. Without it, instruments import at $0 per hour.
To change many instruments at once, choose Export under Equipment & access, edit the file, and import it again. The export has an ID column. Keep it if you rename an instrument, so the row updates the instrument and does not add a new one.
Add one at a time
- Open Equipment and choose Add equipment. Enter the name and the details you keep for it, then save.
- Open Schedule, then Equipment & access. The new instrument is listed as Scheduling not enabled. Choose Set up next to it.
- Set its rules, described in the next section, and choose Save equipment rules. Open for reservations is already ticked.
Set booking rules for each instrument
Each instrument has its own rules. A manager opens Schedule, then Equipment & access, chooses Edit rules next to the instrument, changes the form, and chooses Save equipment rules.
| Field on the form | What it does | Range and starting value |
|---|---|---|
| Open for reservations | Turns booking on. With it off, nobody can make a new reservation or check in. Existing reservations stay on the schedule. | Starts on. |
| Minimum minutes and Maximum minutes | The shortest and longest research session. | 1 to 1,440 and 1 to 10,080 minutes. The form starts at 15 and 480. |
| Book up to this many days ahead | A session must end within this many days from now. | 1 to 365. Starts at 90. |
| Book at least this many hours ahead | The notice a researcher must give, for example 168 hours for one week. Managers can still book inside it. | 0 to 720. Starts at 0. |
| Setup time before each session (minutes) and Cleanup time after each session (minutes) | Time held around every session. Nobody else can book the instrument during it. | 0 to 240 each. Both start at 0. |
| Limit booking to set hours | The days and hours when researchers can book, set with Opens, Closes, and a tick for each day. Managers can still book outside them. | Starts off. Turned on, it starts at 08:00 to 18:00, Monday to Friday. |
| Require training approval for this instrument | Only people with training access can book. | Starts off. |
| Training from a training session lasts (days) | How long training lasts when it comes from a training session. | 1 to 3,650. Blank means no expiry. |
| Require manager approval for each reservation | Every booking becomes a request that a core manager approves or declines. | Starts off. |
| Hold a request awaiting approval for (hours) | How long a request holds its time. It never holds past the session start. 0 holds the time until someone decides. | 0 to 720. Starts at 24. |
| Require a protocol number, such as IACUC, for each reservation | The booking form asks for a protocol number. | Starts off. |
Instruments from the starter list or an import can start with other values, such as a longer minimum session or training turned on.
- Bookable hours. A session must fit inside the hours of one day, and Closes must be later than Opens. The hours are read in the workspace time zone. Until you set one, they are read in each person's own time zone.
- Setup and cleanup. A change applies to new reservations. Reservations already made keep the times they were booked with.
- Limits per person. Open Limits per person to set Hours a week, Hours a month, and Upcoming reservations at a time. Leave a field blank for no limit. Reserved time counts, by calendar week (from Monday) and month. A repeat series is checked as a whole. Core managers can still book past a limit.
- Missed check-ins and forgotten check-outs. Two fields release a reservation nobody checked in to and close a session nobody checked out of. Both start at 0, which turns them off. See No-shows and Sessions left open.
The length, days-ahead, notice, and hours rules apply to research sessions. Maintenance blocks and training sessions that a manager schedules are not held to them. No reservation can be longer than seven days.
Hourly rates, service options, and pricing rules are on the same form. They are part of the Core plan. A new instrument bills by the minute, rounded up; Bill for use and services explains the billing rules and the workspace currency.
Set the workspace time zone
- Open Schedule, then Equipment & access.
- Under Rules for the whole core, choose a zone in Time zone of this workspace. It saves when you choose it.
The starting value is Not set (each person's own time zone). Billing months, prime time, weekly and monthly limits, expiry dates, and bookable hours follow the workspace time zone. The calendar still shows each person their own local time.
The same panel has one more rule for the whole core: A person can hold only one reservation at a time, across all instruments. Core managers can still book overlapping time for someone.
Invite people and set roles
Managers add people on the People page. Everyone signs in with a ConductScience account.
Invite by email
- Under Invite people, paste addresses into Email addresses or a table, one per line or separated by commas.
- Choose a Role and a Pricing group for the people on the list.
- Choose Send invites.
Each invite is tied to its email address and expires in 14 days. The person accepts by signing in with a ConductScience account that uses that address. You can send up to 100 invites at a time. Each result line has Copy link, so you can send the link yourself if the email did not go out. Open invites are listed under Pending invites, with Send again and Revoke.
Invite from a table
Paste a table copied from a spreadsheet, with its header row, into the same box. The columns Email, Role, Pricing group, and Trained on are read. Trained on holds instrument names separated by commas or semicolons. Someone already in the workspace is trained at once. Someone you invite is trained when they accept. Rows with no role or pricing group use the choices under the box.
Share a join link
- Choose Turn on join link, then Copy link, and share the link on your core's website or mailing list.
- People who open the link sign in and ask for access.
- Under Access requests, choose a role and pricing group for each person, then Approve or Decline.
Make a new link replaces the link, and the old one stops working. Turn off closes it.
Roles
| Role | What the person can do |
|---|---|
| Owner | The person who created the workspace. Has everything a manager has. Cannot be changed or removed on the People page. |
| Manager | Runs the core: adds instruments, sets rules and rates, grants training access, approves requests, invites people, and sees every booking. |
| Researcher | Books instruments, checks in and out, and sees their own costs. |
| Viewer | Sees the schedule and cannot change it. |
To change a role, pick a new one in the Role column under Members. To remove someone, choose Remove… and confirm with Remove. Their upcoming reservations are cancelled. You cannot change or remove yourself; another manager does that.
The pricing group sets which rate a person pays. Changing a member's pricing group needs the Core plan.
Training access
When an instrument has Require training approval for this instrument turned on, only people with training access can book it, and the session must end before their training expires. People are emailed two weeks before their training expires.
Grant it to one person
- Open Schedule, then Equipment & access, and find Training & pricing groups.
- Choose the Equipment and the Researcher.
- If your core requires retraining, add a date and time under Approval expiry (optional).
- Choose Grant training access.
Revoke access takes it away. Granting it again with a new expiry renews it.
Turn training checks off
Training is something you choose to require. To open one instrument to everyone, clear Require training approval for this instrument in its rules. To open every instrument at once, for example in a teaching lab where every student and volunteer uses the equipment, a manager clears Check training before booking and check-in under Rules for the whole core.
With checks off, nobody is asked for training when booking, moving, approving, or checking in, at the kiosk or a connected lock too. Each instrument keeps its own setting and the access you granted, so turning checks back on restores them at once. Expiry reminders pause while checks are off.
Grant it to many people
Use the Trained on column when you invite people from a table. It also works for people who are already members.
Run a training session
- Choose + Book equipment and set Reservation type to Training session.
- Pick the instrument and the time, set Seats, and name the session under Session title. Choose Schedule training session.
- People sign up under Schedule, then My reservations, in Training sessions. A manager can also add them there.
- After the session starts, choose Record attendance, tick who came, and choose Save attendance.
Everyone you tick is trained on the instrument for the number of days in Training from a training session lasts (days), or with no expiry when that field is blank. The session holds the instrument for its time, like any reservation.
Next: Book and use an instrument covers what your researchers see, and how requests, no-shows, and open sessions are handled.
Labs and facilities
A core facility workspace has Facilities and Labs in its menu. It starts with one facility named after the workspace, holding all its instruments and services. Workspace owners, admins, and managers add facilities and lab records.
Facilities
- Open Facilities. To run another group of instruments with its own people, choose Add a facility.
- Under Who may book, keep Open: any member of the workspace may book, or choose Linked labs only: a booking must be for a linked lab.
- Under Labs it serves, choose Link lab. Each link has the price group that lab's bookings get.
- Under Managers, staff, finance, and auditors, choose Assign role to give someone a role in this facility.
| Role | What it allows, in that facility only |
|---|---|
| Manager | Sets rules, rates, and training for the facility’s instruments, edits them in the equipment register, links labs, and works the facility’s service requests, including logging time for its staff. |
| Staff | Checks sessions in and out, records usage and no-shows, declines requests that are waiting for approval, and works the service requests for the facility’s services: stages, samples, time, results, and completion. |
| Auditor | Reads the facility’s bookings without changing them. |
A role is granted only by someone with more authority, and nobody can raise their own. Every grant and removal is in the activity log.
With more than one facility, every report under Reports, then Build a report, can be grouped by Facility: an instrument's sessions, problems, and downtime count for its facility, and a request, its stages, and its staff time for the facility of its service. Instruments and services outside every facility show as No facility.
Labs
A lab record is the research group a person books for. Open Labs, choose Add a lab, and use Add person to add its members. Facilities it may book lists its links.
When someone is in more than one lab, the booking form asks which lab the booking is for, and the booking records it. A booking charged to a project is for the project's lab when the person is in that lab or was added to the project by name.