Requests, QC, and billing for proteomics cores
Take protein identification, quantification, phosphoproteomics, and PTM requests with sample sheets, record pass or fail QC on every sample and instrument, follow each stage, and bill the work.

Set up as a proteomics core
Setup adds 10 instruments, 8 services, and 18 maintenance plans.
Follow a request through the core
Pick a service, send the request, and take it through to the invoice.
Services
Protein identification
The proteins in a gel band, a spot, or a solution, such as an immunoprecipitation, identified by LC-MS/MS and a database search. You get the list of proteins found in each sample.
Paste rows from a spreadsheet, or add them one at a time.
Estimated charge $1,080.00
$45.00 per sample × 24 samples.
This brings Aging cohort to $9,080.00 of its $10,000.00 budget.
Who it is for
Proteomics cores
A proteomics sample goes through digestion, labeling, fractionation, LC-MS/MS, and analysis, with checks along the way, on mass spectrometers that must pass QC before they run. ConductCommons keeps each request with its samples, QC results, stages, staff, reagents, and bill, and each instrument with its QC, maintenance, and problems.
What comes set up for a proteomics core
10instruments
8services
18maintenance plans
See every instrument, service, and plan
Instruments10
Mass spectrometer (2)
HPLC system
Vacuum concentrator
Sonicator
Centrifuge
Plate reader
Liquid handling robot
Data processing workstation (2)
Services8
Protein identification
per sample, about 10 days, 5 stages
Label-free quantification
per sample, about 21 days, 6 stages
Isobaric labeling (TMT)
per sample, about 28 days, 8 stages
Phosphoproteomics
per sample, about 28 days, 7 stages
PTM mapping
per sample, about 14 days, 5 stages
Intact protein mass
per sample, about 5 days, 5 stages
Targeted quantification
per sample, about 21 days, 6 stages
Proteomics data analysis help
by the hour
Maintenance plans18
Run the QC standard
every week, on 2 instruments
Mass calibration
every week, on 2 instruments
Clean the ion source
every month, on 2 instruments
Replace the trap and analytical columns
every 3 months, on 2 instruments
Purge the pumps and check the pressure
every month, on 1 instrument
Clean the chamber and check the vacuum
every month, on 1 instrument
Change and degas the water bath
every week, on 1 instrument
Clean the deck and check pipetting
every month, on 1 instrument
Archive raw files and clear space
every month, on 2 instruments
Preventive maintenance visit
every year, on 4 instruments
You can also download free request forms and maintenance logs for this kind of core.
What the core runs
The instruments behind the work
Choose Proteomics when you set up the core, and these open with their booking rules, along with eight services with their stages and usual QC checks, and the maintenance plans. Change anything later, and add any instrument your core shares. Pick an instrument to see its booking rules and maintenance plans.
Instrument status
Updated 10:42 AM on Oct 13; refreshes every minute.
- 1 in use
- 1 booked
- 1 training
- 1 down
- 6 free
Booking rules
- Training
- Needed before booking
- Approval
- A manager approves each reservation
- Session
- 1 hour to 3 days
- Charged for
- Actual usage, check-in to check-out
Preventive maintenance
Managers are emailed before each one is due.
Run the QC standard
every week · next due Oct 19
Mass calibration
every week · next due Oct 18
Clean the ion source
every month · next due Oct 24
Replace the trap and analytical columns
every 3 months · next due Dec 15
Preventive maintenance visit
every year · next due Dec 25
LC-MS/MS systems
Run by staff for service work, with QC standards, mass calibration, and source cleaning on the calendar
HPLC for fractionation
Fractionates peptides before LC-MS/MS, or booked by trained researchers
Sample preparation
Sonicator, vacuum concentrator, centrifuge, plate reader for protein assays, and a liquid handler for digestion
Data processing workstations
Booked for database searches and quantification, with raw files archived each month
How it fits proteomics work
From the sample to the data that goes back
Before the work
Researchers choose a service, species, and acquisition, then list samples with group and protein amount.
Label-free quantification
24 samples, every row checked
| Sample name or ID | Group | Protein amount (µg) |
|---|---|---|
| S-01 | Control | 50 |
| S-02 | Control | 50 |
| S-03 | Treated | 45 |
and 21 more samples
During the work
Each stage has a target in days. Researchers see where their samples are and when the data should arrive.
Protein identification
SR-0042 · Chen Lab
- Done
Received
- Done
Digestion
Target 2 days
- In progress
LC-MS/MS
Target 3 days
- Not started
Database search
Target 2 days
- Not started
Delivered
Staff record each check with a value, so a failed sample is explained before the data goes back.
QC
SR-0042 · Protein identification
- Pass
Peptide yield
24 of 24 samples
- Pass
Proteins identified
Whole request
Recorded by Elena Rossi, Oct 15
Assign each request with a due date. Staff log their time by stage, and analysis help bills by the hour.
Staff time
SR-0042 · Assigned to Elena Rossi · Due Oct 26
- Digestion1.5 hours
- LC-MS/MS6 hours
- Database search4 hours
Label sets and columns come out of stock when a request is done. Managers are emailed at the reorder point.
Taken from stock
Completed requests, Oct 15
- Taken
TMT label set
per request
- At reorder point
Phosphopeptide enrichment column
per sample
After the work
Price each service per sample, or send an estimate. Requests charged to a project can wait for its PI.
INV-0014
Chen Lab · Aging cohort
- $540.00
Protein identification
12 samples at $45.00
- $1,080.00
Label-free quantification
24 samples at $45.00
- $270.00
Isobaric labeling (TMT)
6 samples at $45.00
Total (USD)$1,890.00
See pass rates, turnaround, and charges for each service. Download any table as CSV.
Turnaround by service
Average days, this year
- Protein identification10 days
- Label-free quantification21 days
- Isobaric labeling (TMT)28 days
- Phosphoproteomics28 days
On the instruments
Record each QC standard run with a value. A failed check emails the managers.
Mass spectrometer 1
QC checks
- Pass
Run the QC standard
Oct 24, 8:05 AM · Elena Rossi
- Pass
Run the QC standard
Oct 17, 8:12 AM · Marcus Lee
Everyone who books Mass spectrometer 1 sees the last result.
Mass spectrometers need training and approval by default. The status board shows each one in use, free, or down.
Schedule
Oct 20
Mass spectrometer 1
Mass spectrometer 2
HPLC system
- Booked
- Training
- Maintenance
Managers are reminded of QC standards, source cleaning, and service visits. Downtime tells the people booked.
Maintenance plans
10 plans
- Due Oct 18
Run the QC standard
every week
- Due Oct 22
Mass calibration
every week
- Due Nov 8
Clean the ion source
every month
- Due Dec 19
Replace the trap and analytical columns
every 3 months
Questions
Proteomics core questions
Can we record QC on each sample?
Yes. Staff choose a check, such as protein amount or peptide yield, and mark each sample pass or fail with a value and a note, or record one result for the whole request. Each service lists its usual checks to choose from. The researcher sees the results on the request.
How do we keep track of instrument QC?
Record each QC standard run on the mass spectrometer’s page with its result. A failed check emails the workspace and facility managers, a pass can also record the QC standard plan as done, and the QC report shows the pass rate by instrument, check, and month.
Can the PI approve a request before the work starts?
Yes. Name an approver on the project. A request charged to it waits for their approval, and the core hears of it once it is approved. One that would pass the project’s budget can also wait for a workspace manager.
How is a TMT experiment billed?
Per sample: each channel is a sample at the price for the researcher’s price group, or the core sends an estimate first for the researcher to accept. Completing the request takes the label set from stock.
Does it work with our finance system?
Completed requests and sessions go on a monthly statement for each project or account, locked once final. The journal file lists each finalized line against the payer’s account and your revenue account, for the business office to post.
Run your proteomics core in one place.
Every new workspace includes the Core plan for 30 days. After that, booking stays free; rates, invoices, and service requests need the Core plan.













