Skip to content
ConductCommonsStart free

Requests, QC, and billing for proteomics cores

Take protein identification, quantification, phosphoproteomics, and PTM requests with sample sheets, record pass or fail QC on every sample and instrument, follow each stage, and bill the work.

Protein gels stained blue, with their bands.

Set up as a proteomics core

Setup adds 10 instruments, 8 services, and 18 maintenance plans.

Follow a request through the core

Pick a service, send the request, and take it through to the invoice.

New request

Protein identification

The proteins in a gel band, a spot, or a solution, such as an immunoprecipitation, identified by LC-MS/MS and a database search. You get the list of proteins found in each sample.

Sample name or IDProtein of interestProtein amount (µg)Notes

Paste rows from a spreadsheet, or add them one at a time.

Estimated charge $1,080.00

$45.00 per sample × 24 samples.

This brings Aging cohort to $9,080.00 of its $10,000.00 budget.

Example data.

Who it is for

Proteomics cores

A proteomics sample goes through digestion, labeling, fractionation, LC-MS/MS, and analysis, with checks along the way, on mass spectrometers that must pass QC before they run. ConductCommons keeps each request with its samples, QC results, stages, staff, reagents, and bill, and each instrument with its QC, maintenance, and problems.

What comes set up for a proteomics core

10instruments

8services

18maintenance plans

See every instrument, service, and plan

Instruments10

  • Mass spectrometer (2)

  • HPLC system

  • Vacuum concentrator

  • Sonicator

  • Centrifuge

  • Plate reader

  • Liquid handling robot

  • Data processing workstation (2)

Services8

  • Protein identification

    per sample, about 10 days, 5 stages

  • Label-free quantification

    per sample, about 21 days, 6 stages

  • Isobaric labeling (TMT)

    per sample, about 28 days, 8 stages

  • Phosphoproteomics

    per sample, about 28 days, 7 stages

  • PTM mapping

    per sample, about 14 days, 5 stages

  • Intact protein mass

    per sample, about 5 days, 5 stages

  • Targeted quantification

    per sample, about 21 days, 6 stages

  • Proteomics data analysis help

    by the hour

Maintenance plans18

  • Run the QC standard

    every week, on 2 instruments

  • Mass calibration

    every week, on 2 instruments

  • Clean the ion source

    every month, on 2 instruments

  • Replace the trap and analytical columns

    every 3 months, on 2 instruments

  • Purge the pumps and check the pressure

    every month, on 1 instrument

  • Clean the chamber and check the vacuum

    every month, on 1 instrument

  • Change and degas the water bath

    every week, on 1 instrument

  • Clean the deck and check pipetting

    every month, on 1 instrument

  • Archive raw files and clear space

    every month, on 2 instruments

  • Preventive maintenance visit

    every year, on 4 instruments

You can also download free request forms and maintenance logs for this kind of core.

What the core runs

The instruments behind the work

Choose Proteomics when you set up the core, and these open with their booking rules, along with eight services with their stages and usual QC checks, and the maintenance plans. Change anything later, and add any instrument your core shares. Pick an instrument to see its booking rules and maintenance plans.

Instrument status

Updated 10:42 AM on Oct 13; refreshes every minute.

  • 1 in use
  • 1 booked
  • 1 training
  • 1 down
  • 6 free
  • Booking rules

    Training
    Needed before booking
    Approval
    A manager approves each reservation
    Session
    1 hour to 3 days
    Charged for
    Actual usage, check-in to check-out

    Preventive maintenance

    Managers are emailed before each one is due.

    • Run the QC standard

      every week · next due Oct 19

    • Mass calibration

      every week · next due Oct 18

    • Clean the ion source

      every month · next due Oct 24

    • Replace the trap and analytical columns

      every 3 months · next due Dec 15

    • Preventive maintenance visit

      every year · next due Dec 25

Example data.
  • LC-MS/MS systems

    Run by staff for service work, with QC standards, mass calibration, and source cleaning on the calendar

  • HPLC for fractionation

    Fractionates peptides before LC-MS/MS, or booked by trained researchers

  • Sample preparation

    Sonicator, vacuum concentrator, centrifuge, plate reader for protein assays, and a liquid handler for digestion

  • Data processing workstations

    Booked for database searches and quantification, with raw files archived each month

How it fits proteomics work

From the sample to the data that goes back

Before the work

Core plan

Researchers choose a service, species, and acquisition, then list samples with group and protein amount.

Label-free quantification

24 samples, every row checked

Sample name or IDGroupProtein amount (µg)
S-01Control50
S-02Control50
S-03Treated45

and 21 more samples

Example data.

During the work

Core plan

Each stage has a target in days. Researchers see where their samples are and when the data should arrive.

Protein identification

SR-0042 · Chen Lab

In progress
  • Received

    Done
  • Digestion

    Target 2 days

    Done
  • LC-MS/MS

    Target 3 days

    In progress
  • Database search

    Target 2 days

    Not started
  • Delivered

    Not started
Example data.

Core plan

Staff record each check with a value, so a failed sample is explained before the data goes back.

QC

SR-0042 · Protein identification

  • Peptide yield

    24 of 24 samples

    Pass
  • Proteins identified

    Whole request

    Pass

Recorded by Elena Rossi, Oct 15

Example data.

Core plan

Assign each request with a due date. Staff log their time by stage, and analysis help bills by the hour.

Staff time

SR-0042 · Assigned to Elena Rossi · Due Oct 26

  • Digestion1.5 hours
  • LC-MS/MS6 hours
  • Database search4 hours
Example data.

Core plan

Label sets and columns come out of stock when a request is done. Managers are emailed at the reorder point.

Taken from stock

Completed requests, Oct 15

  • TMT label set

    per request

    Taken
  • Phosphopeptide enrichment column

    per sample

    At reorder point
Example data.

After the work

Core plan

Price each service per sample, or send an estimate. Requests charged to a project can wait for its PI.

INV-0014

Chen Lab · Aging cohort

  • Protein identification

    12 samples at $45.00

    $540.00
  • Label-free quantification

    24 samples at $45.00

    $1,080.00
  • Isobaric labeling (TMT)

    6 samples at $45.00

    $270.00

Total (USD)$1,890.00

Example data.

Core plan

See pass rates, turnaround, and charges for each service. Download any table as CSV.

Turnaround by service

Average days, this year

  • Protein identification10 days
  • Label-free quantification21 days
  • Isobaric labeling (TMT)28 days
  • Phosphoproteomics28 days
Example data.

On the instruments

Record each QC standard run with a value. A failed check emails the managers.

Mass spectrometer 1

QC checks

  • Run the QC standard

    Oct 24, 8:05 AM · Elena Rossi

    Pass
  • Run the QC standard

    Oct 17, 8:12 AM · Marcus Lee

    Pass

Everyone who books Mass spectrometer 1 sees the last result.

Example data.

Mass spectrometers need training and approval by default. The status board shows each one in use, free, or down.

Schedule

Oct 20

  • Mass spectrometer 1

  • Mass spectrometer 2

  • HPLC system

  • Booked
  • Training
  • Maintenance
Example data.

Managers are reminded of QC standards, source cleaning, and service visits. Downtime tells the people booked.

Maintenance plans

10 plans

  • Run the QC standard

    every week

    Due Oct 18
  • Mass calibration

    every week

    Due Oct 22
  • Clean the ion source

    every month

    Due Nov 8
  • Replace the trap and analytical columns

    every 3 months

    Due Dec 19
Example data.

Questions

Proteomics core questions

Can we record QC on each sample?

Yes. Staff choose a check, such as protein amount or peptide yield, and mark each sample pass or fail with a value and a note, or record one result for the whole request. Each service lists its usual checks to choose from. The researcher sees the results on the request.

How do we keep track of instrument QC?

Record each QC standard run on the mass spectrometer’s page with its result. A failed check emails the workspace and facility managers, a pass can also record the QC standard plan as done, and the QC report shows the pass rate by instrument, check, and month.

Can the PI approve a request before the work starts?

Yes. Name an approver on the project. A request charged to it waits for their approval, and the core hears of it once it is approved. One that would pass the project’s budget can also wait for a workspace manager.

How is a TMT experiment billed?

Per sample: each channel is a sample at the price for the researcher’s price group, or the core sends an estimate first for the researcher to accept. Completing the request takes the label set from stock.

Does it work with our finance system?

Completed requests and sessions go on a monthly statement for each project or account, locked once final. The journal file lists each finalized line against the payer’s account and your revenue account, for the business office to post.

Run your proteomics core in one place.

Every new workspace includes the Core plan for 30 days. After that, booking stays free; rates, invoices, and service requests need the Core plan.

Photo credits